创建于2024.08.15

How to calculate the actual required pump head?

How to calculate the actual required pump head?

In real life, we face two water extraction situations, one is surface water and the other is groundwater.
For surface water, we can generally use solar land pumps. For groundwater, solar submersible pumps are generally used.
The following are the methods for the actual lift required for pumping groundwater and surface water:

How to calculate water lift head? (groundwater)

0
* h1 Underwater head (height between the pump and the water surface)
* h2 Height above the water surface (height between the water surface and the wellhead)
* h3 Horizontal distance between the well and the water tank
* h4 Height of the water tank
Actual required head: H = h1/10 + h2 + h3/10 + h4

How to calculate water lift head? (surface water)

0
* h3 Horizontal distance from water source to water tank
* h4 Vertical height from water source to water tank
Actual required head: H=h3/10 + h4
Hope this would be helpful.
Thanks

We are committed to excellence in everything we do and look forward to working with you!

QUESTIONS OR CONSULTING

Contact Information

Fill up the form and we’ll get back to you in few hours.

+86 18437927523

eloy.zhao@solar-gs.com

Guangdong, China

Call Us

+8618437927523

GenSolar

Product 

Copyright ©️ 2022, Shenzhen GengSheng New Energy Co., Ltd. All Rights Reserved.

Contact us

Shenzhen GengSheng New Energy Co., Ltd

Email: Eloy.zhao@solar-gs.com

Phone: +8618437927523

Skype: live:63bfb900a7c1db93

No. 27, Lane 4, Changtang Road,Yutang Street, Guangming District, Shenzhen, Guangdong, China

Better product, Better service, Better life

Whatsapp

WeChat

WhatsApp